In short
  • Pump → flow. It moves a volume of oil per minute (L/min). It does not create pressure by itself.
  • Load → pressure. Pressure rises until it can push the load: p = F ÷ A.
  • Directional valve → direction. It chooses which side of the piston gets oil and which side drains to the tank.
  • Cylinder → force and speed. F = p × A and v = Q ÷ A.
  • Relief valve → limit. At its setting it opens and returns oil to the tank, capping the pressure.

What is a hydraulic system?

Hydraulics is the use of a pressurised liquid to produce force and motion. Bosch Rexroth’s training material describes it as the science of stationary and flowing fluids which, in technical practice, means generating forces and motion with hydraulic fluid.

Every basic circuit has the same five jobs: a power input (the pump), control (valves), a power output (cylinders or hydraulic motors), conductors (hoses, tubes and lines) and the fluid that carries the energy. Oil is hardly compressible, so a cylinder moves as oil enters it and holds still when the oil is trapped. That is why hydraulics can move and hold heavy loads with compact parts.

The parts of a basic hydraulic circuit

Following the oil from the reservoir and back again, a basic cylinder circuit has eight parts. Select any part in the lab to see what it is doing at that moment.

Reservoir (tank)
Holds the oil and receives everything that returns from the valve and the relief valve.
Suction line
Carries oil from the reservoir to the pump inlet. Atmospheric pressure pushes the oil in, so it must not be restricted.
Motor and pump
The motor turns the pump; a fixed-displacement pump delivers a set volume per revolution.
Pressure-relief valve
A spring-loaded valve that opens at its setting and returns oil to the tank, capping the system pressure.
Pressure line and gauge
Carry the pump flow to the directional valve; the gauge shows the pressure the circuit is working at.
Directional control valve
Connects the pump (P) and tank (T) ports to the cylinder ports (A and B) in the pattern selected.
Double-acting cylinder
A piston and rod in a barrel. Oil at the cap end extends it; oil at the rod end retracts it.
Return line
Brings the oil pushed out of the cylinder back through the valve to the reservoir.

How does a hydraulic pump produce flow?

A positive-displacement pump traps a fixed volume of oil at its inlet and pushes it out of its outlet on every revolution. Its flow is set by displacement and shaft speed, Q = V × n: in theory, a pump displacing 13.3 cm³ per revolution at 1,500 rpm delivers about 20 L/min.

The pump does not “suck” oil up. As its chambers open, the pressure at the inlet drops below atmospheric pressure, and atmospheric pressure on the oil in the reservoir pushes oil through the suction line. A clogged inlet strainer or a long, narrow suction line can starve the pump and cause cavitation.

A fixed-displacement pump does not create pressure; it creates flow. Change the pump flow in the lab: the rod speed changes, but the pressure stays where the load puts it. Real pumps leak internally, so their actual flow falls slightly as pressure rises; the lab ignores this.

Where does hydraulic pressure come from?

Pressure builds when flow meets resistance. In a cylinder circuit the main resistance is the load, so the pressure rises to whatever is needed to move it: p = F ÷ A. Friction in hoses, fittings and valves adds a little more.

With the lab’s 63 mm bore (piston area ≈ 3,117 mm²), a 20 kN load needs 20,000 N ÷ 3,117 mm² ≈ 64.2 bar (1 N/mm² = 10 bar). Double the load and the pressure doubles; remove the load and the pressure falls close to zero, although the pump still delivers the same flow.

Pressure is not the same everywhere in a working circuit. It is highest at the pump outlet and drops through each restriction, so a gauge close to the actuator says more about the available force than a gauge at the pump.

Pressure vs flow: what is the difference?

Flow is how much oil moves per minute, and it sets speed. Pressure is force per unit area, and it sets force. A circuit needs both to do work, and their product is hydraulic power.

PressureFlow
Symbol and unitsp: bar, MPa or psi (1 bar = 0.1 MPa ≈ 14.5 psi)Q: L/min or gpm (1 US gpm ≈ 3.785 L/min)
ControlsThe force on the pistonThe speed of the piston
Set byThe load and the resistance in the circuit, capped by the relief valvePump displacement × shaft speed, minus leakage and flow sent elsewhere
Measured withA pressure gauge or transducerA flow meter

Hydraulic power is P = p × Q. In practical units, P (kW) = p (bar) × Q (L/min) ÷ 600. At the lab’s default extend setting, 64.2 bar × 20 L/min ÷ 600 ≈ 2.1 kW goes into moving the load.

How does a directional control valve move the cylinder?

A directional valve is a switch for oil. A sliding spool inside the valve body connects the pump port P to one cylinder port and the other cylinder port to the tank port T. Shift the spool the other way and the connections, and the cylinder, reverse.

Valve positionConnectionsCylinder
ExtendP → A, B → TOil enters the cap end and the rod extends
Neutral (tandem centre)P → T; A and B blockedThe pump unloads to the tank at low pressure; the rod is held (leakage ignored)
RetractP → B, A → TOil enters the rod end and the rod retracts

The lab uses a 4/3 valve (four ports, three positions), shifted by solenoids and returned to the centre by springs. Its drawing follows the style of ISO 1219-1 graphical symbols: each square shows the connections of one position, and the active square slides under the ports. Other centre types, such as closed, open or float centres, behave differently in neutral.

How does a hydraulic cylinder produce force?

A cylinder turns pressure into force over the area the oil acts on: F = p × A. When extending, oil pushes on the full piston area; when retracting, it pushes only on the ring-shaped area around the rod.

Apiston = π × D² ÷ 4Aring = π × (D² − d²) ÷ 4F = p × A

Example: 63 mm bore, 36 mm rodExtend (piston area)Retract (ring area)
Effective area3,117 mm²2,099 mm²
Theoretical force at 160 bar49.9 kN33.6 kN

These are theoretical forces. Seal friction and back pressure on the opposite side of the piston reduce what reaches the rod. To estimate a real cylinder, start from its documented bore, rod and pressure: the cylinder worksheet shows every assumption.

Why are extending and retracting different?

With the same pump flow and pressure, a single-rod cylinder extends with more force but less speed, and retracts with less force but more speed, because the rod takes up part of the area on one side of the piston.

20 kN load, 20 L/minExtendRetract
Effective area3,117 mm²2,099 mm²
Pressure needed64.2 bar95.3 bar
Rod speed107 mm/s159 mm/s
Time for a 400 mm stroke3.7 s2.5 s
Return flow to the tank13.5 L/min29.7 L/min

The area ratio here is 3,117 ÷ 2,099 ≈ 1.48. The last row surprises many people: when retracting, the cap end empties faster than the pump fills the rod end, so the return line, filter and valve carry about 1.48 times the pump flow. Speed follows v = Q ÷ A; in practical units, v (mm/s) = Q (L/min) × 16,667 ÷ A (mm²).

How does a relief valve protect the circuit?

A pressure-relief valve sets the highest pressure the circuit can reach. A spring holds it closed; when the pressure at its inlet reaches the setting, it opens and returns oil to the reservoir, so the pressure cannot rise further.

A fixed-displacement pump keeps delivering flow even when the cylinder cannot move: at the end of its stroke, against a load that is too heavy, or with the valve in a blocked position. Without a relief path the pressure would keep rising until something failed. With one, the pressure stays at the relief setting and the whole pump flow passes over the valve.

That protection has a cost. Oil passing over a relief valve does no useful work: at 160 bar and 20 L/min, about 5.3 kW turns into heat in the oil. Circuits are therefore designed not to hold a cylinder against the relief valve for long; the tandem centre in this lab, for example, returns the pump flow to the tank at low pressure in neutral.

Real machines. Relief settings are chosen by the machine manufacturer for the components in that circuit. Do not adjust a relief valve, loosen a fitting or open a line on a real machine without its service procedure: hydraulic systems can hold stored pressure after shutdown, and oil escaping under pressure can penetrate skin.

What does this lab assume?

The lab shows the ideal relationships so that cause and effect are easy to see. It is a teaching model, not a prediction for any real machine.

  • Oil is incompressible, and hoses and tubes do not expand.
  • There is no pressure drop in lines, fittings or the valve, and no internal leakage in the pump, valve or cylinder.
  • The pump delivers exactly its set flow at any pressure, and the motor never slows down.
  • The relief valve opens exactly at its setting, with no pressure override.
  • The load is a resisting force that opposes motion in both directions; inertia, acceleration and seal friction are ignored, so speed and pressure change instantly.
  • The cylinder (63 mm bore, 36 mm rod, 400 mm stroke) is an example size, not a product recommendation.

Glossary

Actuator
The part that does the work: a cylinder (straight-line motion) or a hydraulic motor (rotation).
Bar
A unit of pressure: 1 bar = 100 kPa = 0.1 N/mm² ≈ 14.5 psi.
Cap end
The end of the cylinder without the rod; oil here acts on the full piston area.
Rod end
The end the rod passes through; oil here acts on the ring area around the rod.
Ring (annulus) area
Piston area minus rod area: π × (D² − d²) ÷ 4.
Displacement
The volume a pump moves per revolution, usually in cm³/rev.
Flow rate (Q)
The volume of oil moving per unit time, usually in L/min.
Pressure (p)
Force per unit area. In a circuit it is set by the resistance the flow meets.
Relief setting
The pressure at which the relief valve opens and limits the system pressure.
Spool
The sliding part inside a directional valve that opens and closes the paths between ports.
Tandem centre
A neutral position that connects P to T and blocks A and B, unloading the pump and holding the actuator.
Stall
The actuator stops because the load needs more pressure than the relief setting allows, or because it has reached the end of its stroke.
Cavitation
Vapour bubbles that form when pressure falls too low, usually at a starved pump inlet, and collapse violently.
Hydraulic power
Pressure × flow; P (kW) = p (bar) × Q (L/min) ÷ 600.

Frequently asked questions

Does a hydraulic pump create pressure?

No. A pump creates flow. Pressure builds only when that flow meets resistance, mostly from the load. With no load, the same pump runs at close to zero pressure.

Why does a hydraulic cylinder retract faster than it extends?

The rod occupies part of the piston area on the rod side, so less oil is needed for each millimetre of travel. With the same flow, the rod moves faster when retracting; with the same pressure, it pulls with less force than it pushes.

What happens when a cylinder reaches the end of its stroke?

The oil has nowhere to go, so the pressure rises until the relief valve opens. The pump flow then returns to the tank over the relief valve at the set pressure, and its energy becomes heat.

Is pressure the same everywhere in a hydraulic system?

In oil at rest, pressure acts equally in all directions (Pascal’s principle). In a working circuit, oil loses pressure through every hose, fitting and valve, so pressure is highest at the pump outlet and lower near the actuator.

How is hydraulics different from pneumatics?

Hydraulics uses a liquid, which is hardly compressible, so cylinders can hold position and produce high forces from compact parts. Pneumatics uses compressed air, which is compressible, and generally suits faster motion with less force.

What does a directional valve do in neutral?

That depends on its centre type. In the tandem centre used here, the pump flow returns to the tank and both cylinder ports are blocked. A closed centre blocks all four ports; a float centre connects both cylinder ports to the tank so the rod can be moved by outside forces.

Can I use this lab to size a cylinder or set a relief valve?

No. It uses ideal equations and an example cylinder. Sizing a real system needs the machine’s data, losses, safety factors and the manufacturers’ ratings, and relief settings belong to the machine’s own documentation.

Sources and how this lab was made

HydraResolve designed the circuit, the artwork, the code and the text on this page. The equations are the standard introductory relationships shown above; the lab recalculates them in your browser and does not store your inputs. The explanations were checked against:

Published by HydraResolve; last updated . How the site checks its content is described in the methodology. Send corrections to [email protected].